Universal multifunctional portable device (the class of Radionuclide Identification Devices) designed for search, detection, localization and identification of radionuclide composition of radioactive and nuclear materials, and for quick and accurate measurement of dose rate and count rate (ensuring the radiation safety while localization and identification of radioactive sources) due to having three built-in detectors of different types: highly sensitive NaI spectroscopic detector of gamma radiation, G-M tube for registering high dose rate, and neutron detector (optional).
The instrument has the possibility to connect external detection unit of alpha and beta – it allows to search the alpha and beta sources and measure alpha and beta flux density from contaminated surfaces. The devise has built-in GPS module and can be integrated into the Polimaster Nuclear Protection Network (Polimaster NPNET™) with wireless and wired transfer of radiological data and geographic coordinates to the Remote Expert Center. Modification without neutron channel is available. The products is undergoing final testing and will be available soon. |
РМ1410 – portable, compact (for its class), complex universal device of the expert level. According to its functional abilities, technical parameters and design the instrument fully belongs to the class of Radionuclide Identification Devices and primarily designed to confirm the detection of radiation sources when they are found by stationary radiation portal monitors installed at checkpoints of various radiation-dangerous objects and controlled areas. The device can also be used for secondary – expert – identification of radionuclide composition in case of impossibility to clearly interpret the results obtained using other types of equipment, like Spectroscopic Personal Radiation Detectors.
The device has built-in highly sensitive NaI(Tl) spectroscopic scintillation detector which allows to:
To expand the dose rate measurement range to 10 Sv/h (1000 R/h) PM1410 has built-in G-M tube.
Additionally the device can be equipped with neutron detector for search and detection of neutron sources. *,**
The instrument had the built-in GPS module and so has the possibility to be integrated into the Polimaster Nuclear Protection Network (Polimaster NPNET™) with wireless (Wi-Fi, GSM/GPRS) and wired (USB) transfer of radiological data and geographic coordinates to the Remote Expert Center. It makes the device a complete multifunctional complex to solve a wide range of problems of radiation control and ensuring radiation safety.
There is a possibility of wired (RS485 interface) or wireless (Bluetooth)** connection of external detection unit of alpha and beta, which allows to search and detect the alpha and beta sources and control the surface alpha and beta contamination.
The distinctive feature of the device - the quick and reliable radionuclide identification of radioactive sources even in the presence of shields, containers or other forms of physical protection of radiation sources that have a weakening and scattering influence. This feature is implemented using the integrated algorithm of reverse recalculation of initial gamma radiation in the undistorted spectrum considering statistical interaction processes between radiation and shielding material, and considering thickness of the screen or container.
Also there is a possibility of wireless integration of PM1410 (as dosimetric, radiometric and spectrometric instrument) with radiation portal monitors РМ5000А with transfer of dosimetric, radiometric and spectrometric data into a common base and generation of a unified report.
The delivery package can include telescopic extension tube which is used to:
- fix detection unit of alpha and beta – search and detection of the alpha and beta sources in hard-to-reach locations;
- connect USB camera *** - demonstration (on the built-in screen) of the image of hard-to-reach and potentially dangerous places.
* 3-He detector (detectors with different detection principle may be used).
** Available as an additional option.
*** The camera in not included in the delivery package (purchased by the user).
| PM1410 Identifier | |
|---|---|
| Detector | NaI(Tl) |
| Sensitivity, no less than | |
On 241Am | ![]() |
On 137Cs | 800 s-1/(μSv/h) 8,0 s-1/(μR/h) |
| Energy range of gamma radiation | 0.025 - 3.0 MeV |
| Energy range in Search Mode | 0.025 - 3.0 MeV |
| Coefficient n setting range, (the number of mean square deviations of background) | 1.0 – 9.9 |
| The number of accumulation channels of the scintillation spectra | 1024 |
| The number of spectra, stored in non-volatile memory | up to 1000 |
| Detection of gamma radiation sources at a distance of 0.2m (0.7 ft ), velocity of 0.5 m/s (1.64 ft/s ) and level of radiation background of no more than 0,25 μSv/h (25 μR/h) when the activity of the sources is | |
133Ba | 55.0 kBq |
137Cs | 100.0 kBq |
60Co | 50.0 kBq |
| Detection of the sampling sources at a distance of 0,2m (0.7 ft), velocity of 0.5m/s (1.64 ft/s) and level of radiation background no more than 0,25 μSv/h (25 μR/h) when the weight of the sources is | |
Pu | ![]() |
U | ![]() |
| Neutron search channel | |
| Detector | Slow neutron counter |
| Energy range | from thermal (0,025x10-6 MeV) to 14 MeV |
| Coefficient n setting range, (the number of mean square deviations of background) | 1.0 - 9.9 |
| Detection of the 252Сf alternative source with neutron flux 1,5х104 s-1 at a distance of 1 m (3.28 ft ), velocity of 0.5 m/s (1.64 ft/s) and the level of radiation background of no more than 0.25 μSv/h (25 μR/h ), equivalent of plutonium | 250 g |
| Measuring gamma-channel | |
| Detector | GM-counter |
| Dose equivalent rate measurement range (DER) | 0,1 µSv/h - 10 Sv/h |
| Energy range | 0.015 - 15 MeV |
| Energy response relative to 0.662 MeV (137Cs) in the photon radiation measuring mode, (%) no more: | |
-within the energy range from 0.015 up to 0.045 MeV | ±40% |
-within the energy range from 0.045 up to 15.0 MeV | ±30% |
| The allowable limits of the main relative error of DER measurement (where H is the DER value in mSv/h) | ± (15 + 0,0015/H) % |
| Measuring alpha and beta channel | |
| Detector | Proportional counter |
| Alpha-flux density measurement range | from 1 min-1cm-2 to 5x105 min-1cm-2 |
| The minimal detectable flux density | from 2 min-2cm-1 |
| The limits of allowable main relative error of measurement of the α- flux density on 239Pu (where φ - the measured density of α-flux in min-1cm-2 А coefficient equal 450 min-1cm-2) | ± (20 + А/φ)% |
| β-flux density measurement range | from 10 to 106 min-1cm-2 |
| The limits of allowable main relative error of measurement of β-particles within the range on 90Sr+90Y (where φ - the measured density of β-flux in min-1cm-2 А, coefficient equal 60 min-1cm-2) | ± (20 + А/φ)% |
| General specifications | |
| Identification of radionuclides: | |
Special nuclear materials | 233U, 235U, 237Np, Pu |
Medical radionuclides | 67Ga, 51Cr, 75Se, 89Sr, 99Mo, 99mTc, 103Pd, 111In, 123I, 125I, 131I, 131Cs, 153Sm, 201Tl, 133Xe |
Naturally occurring radioactive materials | 40K, 226Ra, 232Th and daughters, 238U and daughters |
Industrial radionuclides | 57Co, 60Co, 90Sr/90Y, 133Ba, 137Cs, 192Ir, 226Ra, 252Cf |
| Alarming devices | visual, audial |
| Data transfer communication channels | USB, GSM/GPRS, Bluetooth*, Wi-Fi, GPS |
| Battery lifetime | 12 hours |
| Battery | Accumulator battery |
| Operating conditions | |
temperature range, °С (°F ) | -30°C to 50°C (-22°F to 122°F) |
relative humidity at 35 °С (95 °F ) | up to 95% |
| Protection degree | ![]() |
| Weight | 2.7 kg |
| Dimensions | 120х240х178 mm |